DS-UPS1000
HIKVISION UPS
- Compact size
- Overload, discharge, & overcharge protection
Specifications
| Compact size, Excellent microprocessor control guarantees high reliability |
| 1000VA/600W, 12V/9Ah Battery x1 |
| Typical recharge time: 10 to 16 hours |

PL-800Z
KOSS UPS
- Multi-step Boost and Buck Voltage Regulator
- USB Charger Port
- Tel / ISDN Modem Port (RJ-45) Protection
- Built-in Surge and Spikes Protection
- Lightning Surge Arrestor
Specifications
| Spike Suppression |
| 4 x British Output Sockets |
| Resettable Circuit Breaker |
| Microprocessor Controlled Stabilizer |
| Digital Meters Display |
| Start-up Delay Function |
| High Voltage and Low Voltage Protection |
| Short Circuit & Overload Protection |
| Power-back Surges Protection |
| Overheat Protection |

PL-1000Z
KOSS UPS
- Multi-step Boost and Buck Voltage Regulator
- USB Charger Port
- Tel / ISDN Modem Port (RJ-45) Protection
- Built-in Surge and Spikes Protection
- Lightning Surge Arrestor
- Spike Suppression
- 4 x British Output Sockets
- Resettable Circuit Breaker
- Microprocessor Controlled Stabilizer
- Digital Meters Display
- Start-up Delay Function
- High Voltage and Low Voltage Protection
- Short Circuit & Overload Protection
- Power-back Surges Protection
- Overheat Protection
Specifications
| Capacity | 1000VA |
| INPUT | |
| Phase | Single Phase,2 Wires + Earth |
| Voltage Range | 170 VAC – 260 VAC |
| Frequency Range | 50/60 Hz |
| OUTPUT | |
| Waveform | Sinewave (Depends on Input Voltage) |
| Efficiency | 98% |
| Voltage | 230 VAC |
| Voltage Regulation | ±5% |
| Frequency Range | 50/60 Hz |
| Connection | 4×British Sockets |
| STATUS INDICATORS | |
| Indicador Display | Digital Output Voltage,6 seconds Delay Timer, LED×3 |
| Normal | Green Lighting |
| Boost & Buck | Yellow Lighting |
| PROTECTION | |
| High Voltage Protection | Yes (Digital) |
| Circuit Breaker | Short Circuit/Over Voltage |
| Phone/Fax/Modern Line | RJ45 |
| USB CHARGER PORT | |
| Max Current | 1000mA |
| Standard | 500mA |
| SAFETY STANDARD | CE,EN60950,EN55024 |
| Operating Temperature | 0°C-40°C |
| Storage Temperature | |
| Operating Relative Humidity | 10-95% RH (Non-condensing) |
| PHYSICAL | |
| Dimensions (W×D×H)(mm) | 145×207×119 |
| Net Weight(kg) | 2.5 |

Sylion S-EU Series
KOSS UPS
- Capacity 850VA – 3000VA
- LED Display or LCD Display Selectable
- Microprocessor-based Digital Control
- Boost and Buck AVR for Voltage Stabilization
- Auto Sensing Frequency
- Wide Input Voltage Range
- Cold Start
- Auto Restart when Mains Power is Restored
- Auto Track Mains Phase to Ensure That Inverter Output Voltage Has Same Phase with Utility Voltage, Reducing Transfer Time and Peak Surge
- Intelligent Battery Management: Battery Temperature Compensation to Extend the Battery Life; Three-Stage Charging to Shorten Recharge Time
- Short Circuit, Battery Overcharge / Overdischarge, Overload, Surge Protections
- Automatic Charging in Off Mode
- Optional no-load Shutdown
- Optional RS232 / USB Communication Port and RJ11 / RJ45 Protection
- Unattended Safety Shutdown: System Alarm and Auto Power-On / Off by RS232 or USB Interface Communicating with PC
Specifications
| MODEL | S-2000EU |
| Capacity | 2000 VA |
| INPUT | |
| Voltage | 220 / 230 / 240 V: 162 ~ 295 Vac (145 ~ 295 Vac optional) |
| Frequency | 50 / 60 Hz ± 10% (auto-sensing) |
| OUTPUT | |
| Voltage | 220 / 230 / 240 Vac ± 3% |
| Frequency | 50 / 60 Hz ± 1% (auto-sensing) |
| Waveform | Mains mode: pure sine wave; |
| Battery mode: simulated sine wave | |
| Transfer time | Typical Less than 2ms |
| BATTERIES | |
| Configuration | 12 V / 9.0 Ah x 2 |
| Recharge time | 6 ~ 8 h |
| OTHERS | |
| Humidity | 20 ~ 90% RH @ 0 ~ 40℃ (non-condensing) |
| Noise level | ≤ 45 dB (1 m) |
| Metal case | Net / Gross weight (kg):12.9 / 13.3 |
| Dimensions (W × D × H) (mm):125 × 380 x 225 | |
| Packaged dimensions (W × D × H) (mm):180 × 450 x 295 |